22 CULLIGAN
®
MARK 100 WATER SOFTENER
BEFORE LEAVING THE INSTALLATION SITE
Flush the sanitizing solution from the unit by running it to drain for a minimum of 40 gallons, or initiate a full
recharge cycle (by pushing the 'REGEN.' button twice).
Ensure that the brine tank has water to the level of the float. Add water to the tank with a hose or put the unit
into a full recharge so that the brine refill cycle will fill the tank with the proper amount of water.
The water heater will hold hard water for several days. Advise the customer that the existing water volume
in the tank will need to be used before the hot water is soft. If soft hot water is required immediately, refer to the
water heater owner's manual for the proper method of draining the water heater.
Explain the operation of the softener to the customer. Make sure the customer knows that there will be new
sounds associated with the recharging of the unit. Advise the customer to periodically check and replenish the
salt supply.
Check the approiate softener model box on page 2 of the Owner's Guide. Fill in the hardness and number of
people, and then sign and date the corresponding performance data sheet. Leave the Owner's Guide with the
customer.
Clean up the unit and installation site, removing any soldering, or pipe threading, residues from the equipment
and surrounding area with a damp towel.