6 CULLIGAN
®
MARK 100 WATER SOFTENER
PLACEMENT
Refer to Figure 1 for system placement.
Set the media tank on a solid, level surface near water, drain and electrical facilities. Place the outlet (black
coupling) of the tank on the left.
Set the brine system on a flat, smooth, solid surface as near the media tank as possible.
MOUNT THE CONTROL VALVE
See Figure 2 for a visual on mounting the control valve to the tank.
Remove and discard the protective covers on the tank couplings.
Lubricate the o-rings on the tank couplings with silicone lubricant.
Place the control on the tank couplings and press down firmly.
NOTICE: The white tank coupling is the inlet, and should be located on the inlet side (right side) of the control.
Install the u-clamps on both sides of the control and secure with the screws.
TWELVE INCH SOFTENERS
As shipped from the factory, each control is equipped as a 9-inch unit. A 12-inch eductor nozzle and backwash
flow control are included with each unit for conversion for use with the 12-inch tanks.
NOTICE: To prevent injury, convert unit to a twelve-inch configuration prior to installation.
Refer to Figure 3 for a visual on changing the eductor nozzle and the backwash flow control.
Eductor Nozzle Replacement:
Remove the three screws on the eductor cap and remove the cap.
Remove the eductor assembly.
Remove the eductor screen from the assembly
Remove the blue nozzle and replace it with the beige nozzle. Make sure to put the o-ring on the beige
nozzle.
Reverse the procedure to reassemble. To prevent leaks, ensure that the gasket is in the proper position.
Backwash Flow Control Replacement:
Remove the drain clip and pull the drain elbow straight off.
Remove the backwash flow control located behind the elbow. Put the #3 restrictor in its place.
NOTICE: The number on the flow control should face into the valve body.
Reverse the procedure to reassemble.
FIGURE 1
Brine Tank
Softener
Drain Line
Hard Water In
Heater
Treated Water Out
To
Hose
Bibs
Water
Meter
or
Pump
Installation